ASME SB337 Grade 2 Titanium EFW Heat Exchanger Tubes

What ASME SB337 Covers and What EFW Means

ASME SB337 is the ASME code section designation for the specification that covers electric fusion welded titanium and titanium alloy tube for condensers and heat exchangers; it corresponds to ASTM B337 and is applied together with ASTM B338 when a project is built to the ASME pressure vessel and piping codes. The EFW abbreviation describes the welding process, electric fusion welding, in which the strip edges are joined by an electric arc under inert gas shielding to produce a continuous longitudinal weld.

The finished tube is normally cold reduced and annealed after welding, which converts the cast weld structure into a wrought one and gives uniform mechanical properties around the circumference. EFW tube is a cost effective alternative to seamless tube in the medium diameter and medium wall range, and it is accepted by the code for heat exchanger service provided the specified weld examination and pressure testing are carried out.

Grade 2 Chemistry and Mechanical Requirements

Element Maximum, percent by mass
Iron 0.30
Carbon 0.08
Nitrogen 0.03
Hydrogen 0.015
Oxygen 0.25
Other elements, each 0.10
Other elements, total 0.40
Property, annealed Minimum
Tensile strength 345 MPa
Yield strength, 0.2 percent offset 275 MPa
Elongation 20 percent
UNS number R50400
Density 4.51 g/cm3

Why Grade 2 Is the Standard Choice

Grade 2 is the most widely used unalloyed titanium grade worldwide because its strength sits above Grade 1 while its ductility and weldability remain high. Its oxygen limit of 0.25 percent, higher than the 0.18 percent of Grade 1, provides the additional strength without changing the corrosion behaviour, since the passive film is governed by the titanium dioxide surface rather than by the interstitials. In heat exchanger service this means a tube that can be roll expanded or seal welded reliably, that tolerates the thermal cycling of a condenser, and that resists chlorides, hypochlorite, seawater and most oxidising acids.

Where the process stream is a reducing acid, or where the chloride concentration and temperature are high enough to destabilise the passive film, the palladium bearing Grade 7 or the molybdenum bearing Grade 12 should be substituted for Grade 2 in the same specification.

Size Range, Forms and Delivery Condition

EFW tube for heat exchangers is ordered by outside diameter and wall thickness rather than by nominal bore. Typical supply covers outside diameters from small instrument tube sizes up to about 254 mm, with wall thickness from 0.5 mm to 20 mm, and pipe sizes from 1/2 inch nominal bore to 24 inch nominal bore in schedules from SCH10 to SCH XXS where the tube is used as pipe. Sections include round, square, rectangular and hydraulic forms, and lengths are supplied as single random, double random or fixed cut lengths.

Tubes are supplied in the annealed condition, pickled or bright annealed, with plain or beveled ends and with the weld flash removed where fouling or flow disturbance matters. Straightness, ovality and wall thickness tolerance are stated on the inspection record because they govern the reliability of the tube to tubesheet joint.

Inspection, Testing and Certification

Chemical analysis of the heat and verification of the interstitial elements that distinguish Grade 2.

Tensile testing and hardness testing of the tube in the delivered condition.

Flattening and flare testing to demonstrate weld ductility, and reverse bend testing where specified.

Hydrostatic or pneumatic pressure testing of each tube, with the test pressure recorded.

Eddy current examination of the weld seam and, where required, ultrasonic examination of the tube body.

Positive material identification to confirm the grade and prevent substitution.

Dimensional inspection covering outside diameter, wall thickness, length, straightness and ovality.

Documentation is issued as a mill test certificate to EN 10204 3.1 with the heat number traceable through strip supply, welding and annealing, and third party inspection reports can be provided for project orders. Packing in wooden boxes with end caps and bundle marking protects the bright surface during shipment and allows the tubes to be identified on site.

Frequently Asked Questions

Q: Is ASME SB337 the same as ASTM B337?

A: The material requirements are equivalent; the ASME designation applies when the component is designed and certified under the ASME code, and the tube is normally ordered against the paired ASTM B337 and B338 requirements.

Q: What does EFW mean in tube supply?

A: Electric fusion welded, meaning the tube is formed from strip and joined by an electric arc weld under inert gas shielding, then cold worked and annealed.

Q: Which grade is used most in titanium heat exchangers?

A: Grade 2, because it offers the best balance of strength, ductility, weldability and corrosion resistance, with Grade 1 for maximum formability and Grade 7 or Grade 12 for aggressive reducing media.

Q: What is the typical wall thickness for EFW titanium tube?

A: Heat exchanger tube is commonly supplied between 0.5 mm and 1.2 mm wall for condensers, with thicker walls up to about 20 mm available for higher pressure or larger diameter service.

Q: How is the weld seam inspected?

A: By eddy current examination of the seam in the delivered condition, supported by flattening and flare tests on samples from the lot and hydrostatic or pneumatic pressure testing of the finished tubes.