Mar 20, 2024 Leave a message

ASTM-B338.pdf

ASTM B338 Grade 2 Titanium Coils: Uses and Benefits

What Titanium Coils Are

A titanium coil is a continuous length of tube wound into a helix or serpentine, immersed in a vessel to heat or cool its contents. The service fluid flows inside the tube, while the tank liquid bathes the outside, transferring heat through the tube wall. Coils are the simplest way to add heat transfer capacity to an existing tank, and they are used in plating baths, chemical reactors, storage tanks and seawater systems.

ASTM B338 Grade 2 tube is the standard coil material because it combines corrosion resistance with the ductility needed to bend the tube into tight coils without cracking. Grade 2, UNS R50400, has a minimum tensile strength of 345 MPa and elongation of at least 20 percent, which supports both the coiling process and the pressure of the service fluid.

Why Grade 2 Titanium for Coils

Coil service is among the most corrosive in industry: the tube is immersed in the process liquid on one side and carries the heating or cooling medium on the other, so both surfaces must resist attack. Titanium resists the chloride plating baths, acids and seawater that corrode steel, stainless and copper coils, and it is immune to the pitting and crevice corrosion that defeat other metals at the liquid line.

The oxide surface is also low-fouling: scale and deposits adhere poorly, so the coil keeps its heat transfer performance longer and needs less frequent cleaning. Where the tank liquid is sensitive to contamination, the inert titanium surface protects product quality, which matters in food, pharmaceutical and electronic plating services.

Types of Titanium Coils

Helical coils wind the tube in a spiral around a central axis, providing maximum surface area in a cylindrical tank, while serpentine or grid coils run back and forth in a flat pattern for rectangular tanks and for immersion near the vessel wall. Both types are produced from straight tube by bending with mandrels, and the finished coil is pressure tested before delivery.

Coils may be supplied with integral inlet and outlet stubs, mounting brackets and protective guards against mechanical damage. For large duties, multiple coils are manifolded in parallel, and for fouling services the coil spacing is set to allow cleaning access between turns.

Benefits in Service

The dominant benefit is reliability: a titanium coil in a plating bath or acid tank lasts for years, while steel coils are replaced every few months. The saving includes not only material but also the production loss during change-out, which often exceeds the coil cost itself. Titanium coils also remove the risk of bath contamination by corrosion products, which is critical in electroplating where metal ions ruin deposit quality.

Heat transfer is competitive because the smooth surface and thin wall keep the overall coefficient high, and the low fouling tendency maintains it in service. The coil is light, so installation into an existing tank needs no heavy lifting equipment, and the ductility of Grade 2 allows field adjustment of the coil shape to fit the vessel.

Design and Installation Practice

Coil design starts with the required heat duty, the available temperature difference and the overall heat transfer coefficient, then selects tube diameter, wall thickness, coil diameter and pitch. Wall thickness is sized for the internal pressure using Grade 2 allowable stresses, with an allowance for external hydrostatic load from the tank liquid. The bend radius follows the tube diameter, and the coil supports prevent sagging and vibration.

Installation lowers the coil into the tank, connects it to the service fluid supply with titanium or lined piping, and pressure tests the circuit. The tank liquid level is kept above the coil, and the coil is positioned clear of agitators and tank internals. With this practice, a Grade 2 titanium coil delivers decades of maintenance-free service.

Frequently Asked Questions

Q: What are titanium coils used for?

A: They heat or cool corrosive liquids in plating baths, chemical reactors, storage tanks and seawater systems, using a coiled tube immersed in the vessel.

Q: Why is Grade 2 titanium the standard coil material?

A: It combines full corrosion resistance in chlorides and acids with the ductility needed to bend tight coils and the strength to hold service pressure.

Q: Can titanium coils be cleaned in place?

A: Yes, the smooth oxide surface resists fouling and can be cleaned with the same agents used for the tank, within the corrosion limits of the grade.

Q: What tube sizes are used for titanium coils?

A: Typical diameters range from about 10 to 50 mm with walls from 1 mm, selected by heat duty, pressure and the bend radius of the coil geometry.

Q: Do titanium coils need corrosion protection?

A: No, the self-healing oxide film provides the protection, so no coatings, inhibitors or anodes are required in normal service.