Mar 04, 2024 Leave a message

Research On Titanium Tubes For Power Plants

Through a large number of tests and application examples, it has been proved that the application of titanium tubes in power plant condensers has great technical and economic advantages. On the economic side, taking the price of the tube diameter of 1000MW condenser nuclear power unit (about 50000 condenser tubes) in Japan as an example, according to the 40-year usage time of the condenser, the average annual leakage of aluminium-copper tubes is lo, and the titanium tubes have no leakage in 40 years. This paper mainly discusses the problems of titanium tube in power station applications.

1. Corrosion problems

Seawater is used as cooling water for condensers in coastal power stations. As seawater contains a large number of sediments, suspended solids, marine organisms and a variety of corrosive substances, alternating between seawater and river water in brackish water the situation is more serious. The traditional corrosion methods of copper platform metal pipelines include overall corrosion (uniform corrosion), erosion, stress corrosion, etc. Due to the excellent corrosion resistance of titanium, the seawater leakage accident caused by the corrosion of titanium tube condenser has been eliminated. However, since the corrosion resistance of titanium tubes is not as good as that of copper alloy tubes, toxic substances are produced on their surface. As a result, marine organisms tend to adhere to the inner wall of the titanium tube, affecting the heat transfer effect. Therefore, corresponding cleaning devices are needed.

2. Hydrogen absorption

Although titanium has a dense passivation film on its surface and has high corrosion resistance in many strong corrosive media, the affinity between titanium and hydrogen is very high. It readily absorbs hydrogen. It occurs at room temperature and rapidly absorbs hydrogen at high temperatures (e.g. 100°C). The solid solution limit of hydrogen in titanium is very small (about 20 ppm). If the limit is exceeded, hydride (tth2) will precipitate on the titanium surface. The impact value and elongation of titanium decreases rapidly as the surface titanium content increases. In addition, during the renovation of old units, cathodic protection devices are required to prevent galvanic corrosion because copper alloys are used for tube sheets and titanium alloys are used for condenser tubes. For example, the condenser of Hitachi Power Plant is cooled by seawater and the titanium tubes are paired with copper alloy plates. When the protection potential is lower than 0.75V (SCE), hydrogen is absorbed at the end of the outlet titanium tube, and the hydrogen content reaches 650 ppm after one year of use. if the potential is 0.5~0.75V (SCE), the titanium will not absorb hydrogen at room temperature.

3.Vibration problem

Zibo titanium tube has good corrosion resistance. Titanium condensers will not be damaged by corrosion leakage, but titanium tubes may be damaged by vibration. In order to avoid vibration problems with titanium tubes, it is necessary to determine the proper diaphragm spacing when manufacturing a titanium condenser; in the process of retrofitting an old unit, it is necessary to investigate whether the original diaphragm spacing is suitable for titanium tubes.

Send Inquiry

whatsapp

Phone

E-mail

Inquiry